Low-dose protocol for head CT in evaluation of hydrocephalus in children

儿童脑积水评估中头部CT低剂量扫描方案

阅读:1

Abstract

BACKGROUND: A suspicion of ventriculo-peritoneal shunt failure is classified as the most common indication for CT in children with hydrocephalus. The main target of the study was to evaluate the diagnostic value of a low-dose protocol and to compare a total DLP received by patients in compared protocols. MATERIAL/METHODS: Our retrospective analysis included 256 examinations performed in patients aged from 1 month to 18 years, with body mass ranging from 3 to 100 kg. The examinations were conducted in the years 2009-2011. A total number of 128 examinations were performed on the basis of the low-dose protocol and 128 according to a standard protocol using the Siemens SOMATOM Definition AS 128-slice scanner. RESULTS/CONLUSIONS: The analysis showed a full value of the diagnostic low-dose protocol with a simultaneous decrease of the total dose of DLP to the average of 40%. Application protocol with lower mAs in assessing the causes of ventriculo-peritoneal shunt failure in children with hydrocephalus is coherent with the valid principles of radiation protection in pediatrics and reduces the total DLP while maintaining a very good diagnostic value.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。