[Effects of the resin base and retention depth on fracture resistance of molars restored with nano-ceramic endocrowns]

[树脂基底和固位深度对纳米陶瓷内冠修复磨牙抗折强度的影响]

阅读:2

Abstract

OBJECTIVE: To compare the effects of resin base and different retention depth on the fracture resistance of mandibular molars restored with nano-ceramic endocrowns. METHODS: Forty mandibular molars selected and randomly divided into 5 groups: ① The control group which was consisted of intact teeth, ② the non-resin base group, ③ the 2 mm retention depth group, ④ the 3 mm retention depth group, ⑤ the 4 mm retention depth group, respectively. After tooth preparation, in vitro root canal therapy was conducted, which was followed by endocrown design, production and adhesive of groups ②-⑤. All the samples were under load (N) of the universal mechanical testing machine after embedding. The fracture pattern of each sample was observed under stereomicroscope. Then the microstructure of the fracture surface was observed by scanning electron microscopy. RESULTS: The fracture loads of each group were respectively: the control group fracture load was (3 069.34±939.50) N; experimental groups: fracture load of (2 438.04±774.40) N for the group without resin base; fracture load of (3 537.18±763.65) N for the group with 2 mm retention depth. The fracture load of the retention depth 3 mm group was (2 331.55±766.39) N; the fracture load of the retention depth 4 mm group was (2 786.98±709.24) N. There was statistical significance in the effect of resin base and different retention depth on the fracture loads of molars restored with nano-ceramic endocrown (P < 0.05). Repairable fractures in each group were as follows: control group 2/8, non-resin base group 1/8, retention depth of 2 mm group 1/8, retention depth of 3 mm group 2/8, and retention depth of 4 mm group 0/8. The effects of the retention depth and the presence of resin base on the fracture resistance of the resin nano-ceramic endocrowns were statistically significant (P < 0.05). Scanning electron microscopy showed more arrest lines and small twist hackles on the fracture surface of the restorations with resin base (retention depths of 2 mm, 3 mm, and 4 mm), with cracks extending towards the root. In addition to the characteristics above, more transverse cracks parallel to the occlusal surface, pointing outwards from the center of the pulp cavity retention, were also observed on the fracture surface of the non-resin base restorations. CONCLUSION: When molar teeth with nano-ceramic endocrowns are restored, resin base and the retention depth of 2 mm help the teeth to obtain optimal fracture strength.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。