A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment

用于石膏灌注的新型便携式振动器:对圆柱基台边缘配合的影响

阅读:6
作者:Pâmela Cândida Aires Ribas de Andrade, Leonardo Flores Luthi, Kyle Stanley, Antônio Carlos Cardoso

Conclusion

Within the limitations of this study, it was concluded that a greater accuracy of working cast was achieved when a portable vibrator was used for casting molds.

Material and methods

From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05).

Methods

From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05).

Objective

The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. Material and

Results

Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P<0.05), with GIII significantly lower as compared to the other groups.