Two Cases of Armour Thyroid Interference in Thyroglobulin Monitoring for Thyroid Cancer

两例甲状腺素干扰甲状腺癌甲状腺球蛋白监测的病例报告

阅读:2

Abstract

Thyroglobulin (Tg) monitoring is the biochemical standard for surveillance of recurrent differentiated thyroid cancer (DTC). Several assays are available to quantify Tg levels: immunometric assay (IMA), radioimmunoassay (RIA), and the newer liquid chromatography tandem mass spectrometry (LC-MS). It is well known that a number of entities can interfere with the accuracy of testing, and at this point in time, no one assay perfectly balances high sensitivity with low risk of interference. In this case study, we present two cases in which treatment with desiccated thyroid extract (Armour thyroid) led to a sudden elevation in Tg, which resolved when Armour thyroid was discontinued. This elevation occurred when Tg was measured with both IMA and LC-MS, which suggests direct interference from porcine Tg rather than heterophilic or thyroglobulin antibody (TgAb) interference. We suggest that patients with a history of DTC not be treated with desiccated thyroid extracts consistent with guidelines. Furthermore, more advances need to be made in the area of Tg testing to improve specificity and avoid detection of nonhuman Tg and other similar proteins.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。