Outcome of laparoscopic nephron sparing surgery using a Satinsky clamp for hilar control: a trusted tool (SKIMS experience)

使用Satinsky钳进行肾门控制的腹腔镜肾单位保留手术的结果:一种值得信赖的工具(SKIMS经验)

阅读:2

Abstract

BACKGROUND: Nephron sparing surgery is a well-established surgical procedure for patients with small/bilateral renal masses. During the procedure, hilar control can be achieved by using bulldog clamps individually on the renal vessels, the renal artery alone without clamping the vein, or a laparoscopic Satinsky clamp for en bloc hilar clamping. In our series, we described the outcome of laparoscopic nephron sparing surgery using a Satinsky clamp for hilar control. MATERIALS AND METHODS: All eligible cases with confirmed diagnosis of a renal mass were advised of nephron sparing surgery. The short-term outcomes were evaluated by warm ischemia time (using a Satinsky clamp especially when CT renal angiography was not available), average blood loss, and length of postoperative hospital stay. The oncological outcome was evaluated by noting the surgical margins of histopathological specimen, local recurrence, and distant metastasis. RESULTS: Of 30 cases 20 were male. The mean age was 54.25 years. On preoperative evaluation, 24 cases were T1a stage and the rest were 6 T1b stage. Four tumors were located in the upper pole, 4 in the posterior midpole, and 22 in the lower pole. Twenty-six patients had a low complexity score on RENAL scoring (ie, 4-6) and 4 patients a medium complexity score (ie, 7-9). Three patients were converted to open partial nephrectomy because of technical difficulty in intracorporeal suturing and difficulty in achieving hemostasis. Among these 3 patients, 2 patients had posterior base tumors and 1 had a lower polar tumor. Average blood loss was 350 ml, warm ischemia time was 28.46 minutes, and postoperative stay was 4.55 days. Of 30 specimens for histopathology, 23 (76%) were clear cell renal cell carcinoma (RCC), 4 (13%) were papillary RCC, 1 (3.3%) was chromophobe RCC, whereas 2 (6.6%) were benign (oncocytoma). Margins were free of tumors in all the patients with no recurrence in 2 years of follow-up. CONCLUSION: Laparoscopic partial nephrectomy by using a Satinsky clamp as a tool for en bloc hilar clamping in the proper axis at the hilum takes care of multiple vessels irrespective of size and number, particularly when renal angiography is not available. This technique of en bloc hilar clamping is quite useful especially in developing countries where robotic facilities are not available. The Satinsky clamp decreases blood loss and intraoperative time.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。