Vacuum-assisted stereotactic biopsy for isolated BI-RADS 4 microcalcifications: evaluation with histopathology and midterm follow-up results

真空辅助立体定向活检术治疗孤立性BI-RADS 4级微钙化:组织病理学评估及中期随访结果

阅读:2

Abstract

PURPOSE: The aim of this study was to evaluate the 10-gauge vacuum-assisted stereotactic biopsy (VASB) of isolated Breast Imaging Reporting and Data System (BI-RADS) 4 microcalcifications, using histology and follow-up results. METHODS: From January 2011 to June 2013, VASB was performed on 132 lesions, and 66 microcalcification-only lesions of BI-RADS 4 were included into our study. VASB was performed using lateral decubitis stereotaxy for all patients. Pathologic results of VASB and further surgical biopsies were reviewed retrospectively. Patients who were diagnosed to have benign lesions by VASB were referred for follow-up. VASB and surgical histopathology results were compared to determine the underestimation ratios. RESULTS: Fifteen out of 66 lesions from 63 patients (median age, 47 years; range, 34-88 years) were identified as malignant by VASB. Pathological results after surgery revealed three cases of invasive ductal carcinoma among the 12 VASB-diagnosed ductal carcinoma in situ (DCIS) lesions, for a DCIS underestimation rate of 25%. The atypical ductal hyperplasia underestimation rate was 0% for the three lesions. The follow-up period was at least 10 months, with an average of 22.7 months for all patients and 21.2 months for patients with VASB-diagnosed benign lesions. None of the patients had malignancy during the follow-ups. The false-negative rate was 0% in the follow-up of 48 patients. CONCLUSION: VASB should be the standard method of choice for BI-RADS 4 microcalcifications. This method obviates the need for a surgical procedure in 73% of BI-RADS 4 microcalcification-only patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。