Effect of mechanical assistance of the systemic ventricle in single ventricle circulation with cavopulmonary connection

单心室循环合并腔肺连接时,体循环心室机械辅助的作用

阅读:1

Abstract

BACKGROUND: Previous attempts to support single ventricle circulation mechanically have suggested that a custom-built assist device is needed to push, rather than pull, through the pulmonary circulation. We hypothesized that using a conventional ventricular assist device, with or without conversion of a total cavopulmonary connection to a bidirectional Glenn cavopulmonary connection, would allow assistance by pulling blood through the circuit and improve the cardiac index (CI). METHODS: Cavopulmonary connections were established in each of 5 Yorkshire pigs (25 kg) using ePTFE conduits in a Y configuration with appropriate clamping of the limbs of the Y to achieve a total cavopulmonary Fontan connection (TCPC), superior vena cava cavopulmonary connection (SVC Glenn), and inferior vena cava cavopulmonary connection (IVC Glenn). A common atrium had been established previously by balloon septostomy. Mechanical circulatory assistance of the single systemic ventricle was achieved using a centrifugal pump with common atrial inflow and proximal ascending aortic outflow. The CI was calculated using an ultrasonic flow meter placed on the distal ascending aorta and compared between the assisted and nonassisted circulation for 3 conditions: TCPC, SVC Glenn, and IVC Glenn. The mean pulmonary artery pressure, common atrial pressure, arterial oxygen saturation, partial pressure of arterial oxygen, and oxygen delivery were calculated. RESULTS: The unassisted SVC Glenn CI tended to be greater than the TCPC or IVC Glenn CI. Significant augmentation of total CI was achieved with mechanical assistance for SVC Glenn (109% ± 24%, P = .04) and TCPC (130% ± 109%, P = .01). The assisted CI achieved at least a mean baseline biventricular CI for all 3 support modes. Oxygen delivery was greatest for assisted SVC Glenn (1786 ± 1307 mL/L/min) and lowest for TCPC (1146 ± 386 mL/L/min), with a trend toward lower common atrial and pulmonary artery pressures for SVC Glenn. CONCLUSIONS: SVC bidirectional Glenn circulation might allow optimal augmentation of the CI and oxygen delivery in a failing single ventricle using a conventional pediatric ventricular assist device. The results from our model also suggest that the Fontan circulation itself can be supported with systemic ventricular assistance of the single ventricle.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。