Surface Modification of Ti6Al4V ELI Titanium Alloy by Poly(ethylene-alt-maleic anhydride) and Risedronate Sodium

采用聚(乙烯-马来酸酐)和利塞膦酸钠对Ti6Al4V ELI钛合金进行表面改性

阅读:1

Abstract

With the simultaneous increase in the number of endoprostheses being performed, advances in the field of biomaterials are becoming apparent-whereby the materials and technologies used to construct implants clearly improve the implants' quality and, ultimately, the life of the patient after surgery. The aim of this study was to modify the titanium alloy Ti6Al4V ELI used in the construction of hip joint endoprostheses. This is why the continuous development of biomaterials is so important. This paper presents the results of research for a new application of polymer poly(ethylene-alt-maleic anhydride) as a drug release layer, placed on the surface of a titanium alloy. The obtained layers were analyzed using Raman spectroscopy (spectra and maps), Fourier transform infrared spectroscopy (spectra and maps), contact angle measurements as well as scanning electron microscopy and energy dispersive spectroscopy imaging and topography analysis. The results confirmed that the polymer layer obtained on the plate surface after the alkali heat treatment process is much better-it binds much more polymer and thus the applied drug. In addition, a longer and more gradual release of the drug was observed for the alkali heat treatment modification than for H(2)O(2) solution.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。