STUDY ON THE PATELLOFEMORAL JOINT USING MAGNETIC RESONANCE IMAGING: MORPHOLOGICAL VARIATION OF THE MEDIAL PATELLOFEMORAL LIGAMENT

髌股关节的磁共振成像研究:内侧髌股韧带的形态变异

阅读:6
作者:Alfredo Dos Santos Netto, Marcelo Botelho Soares de Brito, Fabrício Roberto Severino, Leila Rodrigues Andrade Campos, Marcelo Astolfi Caetano Nico, Victor Marques de Oliveira, Nilson Roberto Severino

Conclusion

The morphology of the MPFL varies with the interepicondylar distance and the lateral condyle distance, and with patients' ages.

Results

The average length of the MPFL was 46.4 mm, while the average thicknesses of its patellar insertion, middle third and femoral insertion were, respectively, 1.7 mm, 1.4 mm and 1.2 mm. The thickness of the MPFL correlated positively with the lateral condyle and interepicondylar distance measurements, and negatively with the patients' ages.