Endoscopic Ultrasound-Guided Tissue Acquisition Versus Fine Needle Aspiration for Diagnosis of Pancreatic Ductal Adenocarcinoma

内镜超声引导下组织获取与细针穿刺术在胰腺导管腺癌诊断中的比较

阅读:1

Abstract

OBJECTIVES: Compare the 22G needle versus EchoTip ProCore® 20 (Cook Medical, Bloomington, IN, USA) on their handling, specimen suitability, amount of tissue obtained, diagnostic performance, the possibility of immunohistochemistry, and rate of adverse events. MATERIALS AND METHODS: This is a retrospective, comparative study of consecutively examined patients with pancreatic masses who underwent endosonography-guided fine needle aspiration (FNA) via the 22G needle, and endosonography-guided tissue acquisition (TA) via ProCore 20 (PC20). The operator evaluated needle insertion and subjectively classified the specimen. The pathologist measured the samples, classified the amount of tissue, and determined the influence of bleeding on the interpretation. RESULTS: A total of 129 patients participated in the study, out of whom 52 underwent endosonography-guided FNA with 22G and 77 underwent endosonography-guided TA with a PC20 needle. Malignant lesions were found in 106, and 23 had benign lesions. The duodenal route was used in 62% of patients. The 22G needle was easier to introduce (p=0.0495). However, PC20 obtained a larger amount (p<0.01) with fewer punctures (p<0.001). The PC20 also yielded a larger average microcore diameter (p=0.0032). Microhistology was adequate for 22G and PC20 in 22 (42.2%) and 50 (78.1%) specimens, respectively (p<0.001). Bleeding was not significantly different (p>0.999). Immunohistochemistry was possible in 36 (69.2%) and 40 (51.9%) specimens obtained by 22G and PC20, respectively (p=0.075). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 22G were 93.5%, 100%, 100%, 66.7%, and 94.2%, respectively; and for PC20, it was 95%, 100%, 100%, 85%, and 96.1%, respectively. Mild bleeding was the most common early adverse event, occurring in 2/52 (3.8%) 22G and 4/77 (5.2%) PC20 cases (p>0.05). CONCLUSIONS: The PC20 required fewer punctures and reduced the need for immunohistochemistry as it yielded better and larger microcores. Its ease of insertion into the target lesion makes it a good option to obtain satisfactory microcore specimens in difficult positions, such as the transduodenal route.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。