Asbestosis and small cell lung cancer in a clutch refabricator

离合器翻新厂中的石棉肺和小细胞肺癌

阅读:3

Abstract

OBJECTIVES: To present a case of asbestosis and small cell lung cancer caused by asbestos in a clutch refabricator. METHODS: Exposed surfaces of used clutches similar to those refabricated in the worker's workplace were rinsed, and the filtrate analysed by analytical transmission electron microscopy. Tissue samples were also analysed by this technique. RESULTS: Numerous chrysotile fibres of respirable dimensions and sufficient length to form ferruginous bodies (FBs) were detected from rinsed filtrates of the clutch. Bronchoalveolar lavage fluid contained many FBs, characteristic of asbestos bodies. Necropsy lung tissue showed grade 4 asbestosis and a small cell carcinoma in the right pulmonary hilum. Tissue analysis by light and analytical electron microscopy showed tissue burdens of coated and uncoated asbestos fibres greatly exceeding reported environmental concentrations (3810 FBs/g dry weight and 2,080,000 structures > or = 0.5 micron/g dry weight respectively). 72% Of the cores were identified as chrysotile. CONCLUSIONS: Clutch refabrication may lead to exposure to asbestos of sufficient magnitude to cause asbestosis and lung cancer.