Evidence-Based Criteria for Determining Peripapillary OCT Reliability

基于证据的视乳头周围OCT可靠性判定标准

阅读:1

Abstract

PURPOSE: To assess the impact of OCT signal strength (SS) and artifact on retinal nerve fiber layer (RNFL) measurement reliability and to understand whether glaucoma severity modifies this relationship. DESIGN: Retrospective, longitudinal cohort study. PARTICIPANTS: Two thousand nine hundred ninety-two OCT scans from 474 eyes of 241 patients with glaucoma or glaucoma suspect status. METHODS: We extracted mean RNFL thickness and SS and manually graded scans for artifact. To analyze the effect of SS and artifact on OCT reliability, we (1) created a multilevel linear model using measured RNFL thickness values and demographic and clinical data to estimate the true (predicted) RNFL thickness, (2) calculated model residuals (ΔRNFL) as our reliability measure, and (3) created a second multilevel linear model with splines and interaction terms that modeled overall and quadrant specific reliability (ΔRNFL) as the outcome, using SS and artifact as predictors. MAIN OUTCOME MEASURES: Impact of SS and artifact on ΔRNFL. RESULTS: For SS between 10 and 3, the impact of decreases in SS on OCT reliability is modest (-0.67 to -1.25 ΔRNFL per 1-point decrease in SS; P < 0.05). But at less than 3, changes in SS have a large impact on reliability (-15.70 to -16.34 ΔRNFL per 1-point decrease in SS; P < 0.05). At SS between 10 and 3, decreases in SS tend to have a larger impact on reliability in eyes with severe glaucoma (-1.25 per 1-point decrease in SS; P < 0.05) compared with eyes with mild or moderate glaucoma (-0.67 to -0.75 per 1-point decrease in SS; P < 0.05). The presence of artifact has a significant impact on OCT reliability independent of the effects of SS (-4.76 ΔRNFL; P < 0.05). Artifact affects reliability solely in the quadrant in which it occurs, with artifact in one quadrant showing no impact on ΔRNFL in the opposite quadrant (P > 0.05). CONCLUSIONS: Signal strength decreases down to 3 have relatively mild impacts on OCT reliability. At less than 3, the impact of further decreases in SS on reliability are substantial. The effect of SS on reliability is greater in severe glaucoma. Artifacts result in a decrease in reliability independent of the effect of SS. We propose evidence-based guidelines to guide physicians on whether to trust the results of an OCT scan.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。