Interocular correlation sensitivity and its relationship with stereopsis

双眼相关敏感度及其与立体视觉的关系

阅读:1

Abstract

Stereoscopic vision uses the disparity between the images received by the two eyes to derive three-dimensional estimates. Here, we were interested in providing a measure of the strength of binocular vision alternate to disparity processing. In particular, we wanted to assess the spatial dependence of sensitivity to detect interocular correlation (IOC). Thus we designed dichoptic stimuli composed of bandpass textures whose IOC is sinusoidally modulated at different correlation frequencies and compared sensitivity to these stimuli to that of analogous stimuli modulated in disparity. We observed that the IOC sensitivity is low pass/band pass and increases with stimulus duration and contrast in a similar way to that of disparity sensitivity. IOC sensitivity is only weakly, though significantly, correlated with disparity sensitivity in the population. It could provide an alternate measure of binocular sensitivity.