Optically stimulated luminescence (OSL) dosimetry in irradiated alumina substrates from mobile phone resistors

手机电阻器辐照氧化铝基板的光刺激发光(OSL)剂量测定

阅读:1

Abstract

In this study the dosimetric properties of alumina (Al(2)O(3)) substrates found in resistors retrieved from mobile phones were investigated. Measurements of the decline of optically stimulated luminescence (OSL) generated following exposure of these substrates to ionising radiation showed that 16% of the signal could still be detected after 2 years (735 days). Further, the magnitude of the regenerative dose (calibration dose; D (i)) had no impact on the accuracy of dose estimates. Therefore, it is recommended that the D (i) be set as low as is practicable, so as to accelerate data retrieval. The critical dose, D (CL), and dose limit of detection, D (DL), taking into account the uncertainty in the dose-response relation as well as the uncertainty in the background signal, was estimated to be 7 and 13 mGy, respectively, 1 h after exposure. It is concluded that given the significant long-term component of fading, an absorbed dose of 0.5 Gy might still be detectable up to 6 years after the exposure. Thus, OSL from alumina substrates can be used for dosimetry for time periods far in excess of those previously thought.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。