Detection and quantification of ATP and heavy metal with electronical micro-circuits

利用电子微电路检测和定量ATP和重金属

阅读:1

Abstract

In order to use whole eukaryotic cells as an active element in the detection and amplification of biological signals, for both in vitro and in vivo applications, we have undertaken a first approach to interface live cells and integrated circuit, and evaluate the possibility to develop a microbioreactor. An amplified photodiode system was designed and built as an electronical circuit in a way that it could easily be miniaturised. In parallel micro-chips with silicium chambers were used as microbioreactors to adhere cells. We showed here that this etched silicon chamber allows endothelial and CHO cells spreading, permitting determination of a number of cell properties {\it on line} providing appropriate integrated circuits are designed to perform the desired functions. The photodiode system reacting to the luminescent luciferase system permitted, through the use of appropriate software from a personal computer (PC) connected on line in vitro, the determination of ATP concentration, and using different luciferase transfected bacteria permitted the detection of constitutive or induced luminescence.