The effect of ultrasonic tip working length on fluid dynamics in the root canal during the irrigation procedure: a computational fluid dynamics study

超声尖端工作长度对根管冲洗过程中流体动力学的影响:一项计算流体动力学研究

阅读:1

Abstract

BACKGROUND: Root canal irrigation is essential for infection control during root canal treatment. Ultrasonic irrigation is a common method of root canal irrigation used in the clinical practice; however, the working length of ultrasonic tip can influence the fluid dynamics of the irrigant. Different from previous studies which often utilized simplified models, this study aims to utilize the computational fluid dynamic (CFD) and finite element method to evaluate the flow dynamics characteristics of the irrigation fluid when the ultrasonic tip was placed at different depths in the root canal and to predict crack extension during ultrasonic cleaning, based on the real tooth model. METHODS: Images of the mandibular first premolar teeth were scanned using cone beam computed tomography (CBCT), and then imported into the software for three-dimensional reconstruction. ICEM CFD 18.0 software was used to establish the root canal irrigation. The ultrasonic working tip was positioned at distances from the apex stop of 1 mm, 1.5 mm, 2 mm, 2.5 mm, and 3 mm (i.e., the five different working lengths of the working tip are 10 mm, 9.5 mm, 9 mm, 8.5 mm, and 8 mm) respectively. Irrigation velocity, wall shear stress and volume fraction in the root canal were visualized after setting the computing conditions. A dentin microcrack model was established by ABAQUS 6.14 software to predict crack extension during ultrasonic cleaning. RESULTS: The CFD analysis showed that increasing the work length of the ultrasonic tip significantly increased vapor volume fraction, and wall shear stress, while reducing apical pressure. Notably, despite changes in the placement of the ultrasonic working tip, the velocity of irrigant always gradually decreases within the area 1 mm in front of the working tip. The pressure on the root canal significantly lower than the ultimate tensile strength of dentin. CONCLUSION: Increasing the working length can influence vapor volume fraction, wall shear stress and apical pressure. The pressure on the root canal does not cause the dentin microcrack propagation, in order to provide a reference for clinical application.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。