Cone beam computed tomography findings as prognostic factors for maxillary sinus membrane perforation during maxillary sinus augmentation

锥形束计算机断层扫描结果作为上颌窦增高术中上颌窦膜穿孔的预后因素

阅读:1

Abstract

BACKGROUND: Maxillary Schneiderian membrane (SM) perforation is one of the complications of maxillary sinus (MS) augmentation. The aim of the present study was to analyse cone beam computed tomography (CBCT) findings to identify prognostic factors for SM perforation. MATERIALS AND METHODS: 50 CBCT scans were recruit for the analysis, 39 were suitable for analysis and met the inclusion criteria. Retrospective analysis of clinical and radiological CBCT findings of patients who underwent MS augmentation by lateral approach, divided into study group with SM perforation and control group without. Several radiological parameters were included MS lateral wall width, MS floor width, SM width, shape of the SM, level of MS ventilation, presence of septae, presence of blood vessels in the MS wall, the geometrical shape of the MS and sinus floor, presence of polyps and oroantral communication. RESULTS: A thin MS floor, the presence of a Retention Pseudocyst, the presence of MS septae, a concave sinus floor and a triangular sinus shape are risk factors for perforation of the SM during open MS lift. Statistical significant difference between the groups were found regarding MS floor width. CONCLUSION: Based on the results of this study, it can be concluded that careful analysis of CBCT reveals a number of significant radiological features that can be used to predict potential risks.