Application of a modified osteotomy and positioning integrative template system (MOPITS) based on a truncatable reconstruction model in the precise mandibular reconstruction with fibula free flap: a pilot clinical study

基于可截断重建模型的改良型截骨定位整合模板系统(MOPITS)在腓骨游离皮瓣精确下颌骨重建中的应用:一项初步临床研究

阅读:1

Abstract

BACKGROUND: Mandibular defects can greatly affect patients' appearance and functionality. The preferred method to address this issue is reconstructive surgery using a fibular flap. The current personalized guide plate can improve the accuracy of osteotomy and reconstruction, but there are still some problems such as complex design process and time-consuming. Therefore, we modified the conventional template to serve the dual purpose of guiding the mandible and fibula osteotomy and facilitating the placement of the pre-bent titanium. METHODS: The surgery was simulated preoperatively using Computer-Aided Design (CAD) technology. The template and truncatable reconstruction model were produced in the laboratory using 3D printing. After pre-bending the titanium plate according to the contour, the reconstruction model was truncated and the screw trajectory was transferred to form a modified osteotomy and positioning integrative template system (MOPITS). Next, the patient underwent a composite template-guided vascularized fibula flap reconstruction of the mandible. All cases were reviewed for the total operative time and accuracy of surgery. RESULTS: The procedures involved 2-4 fibular segments in 15 patients, averaging 3 fibular segments per procedure. The osteotomy error is 1.01 ± 1.02 mm, while the reconstruction angular error is 1.85 ± 1.69°. The preoperative and postoperative data were compared, and both p > 0.05. During the same operation, implant placement was performed on four patients, with an average operative time of 487.25 ± 60.84 min. The remaining malignant tumor patients had an average operative time of 397.18 ± 73.09 min. The average postoperative hospital stay was 12.95 ± 3.29 days. CONCLUSIONS: This study demonstrates the effectiveness of MOPITS in facilitating precise preoperative planning and intraoperative execution of fibula flap reconstruction. MOPITS represents a promising and reliable tool for reconstructive surgery, particularly for inexperienced surgeons navigating the challenges of mandible defect reconstruction.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。