The impact of surgical guide design and bone quality on heat generation during pilot implant site preparation: an in vitro study

手术导板设计和骨质量对种植体预备过程中热量产生的影响:一项体外研究

阅读:1

Abstract

BACKGROUND: Surgical guides restrict the flow of cooling agent to osteotomy site, which will lead to a temperature rise that provokes tissue injury. Few studies compared differences in the temperature changes between non-limiting 'conventional' and limiting 'guided' surgical guides during implant site preparation. The objective of this study was to investigate the difference in temperature changes during bone drilling for implant placement using non-limiting and limiting surgical guides at cortical and cancellous bone levels. METHODS: Forty-four bovine rib samples were used for implant bed preparation in this study with a minimum thickness of 11 mm was chosen for the ribs. The bone was stored in a freezer at 10 °C until it was used. On the day of the study, the bone was defrosted and soaked in water at 21 °C for three hours before embarking on drilling to make sure each sample was at the same temperature when tested. Forty-four bone specimens were prepared and randomly allocated to receive either a limiting or a non-limiting surgical guides (22 for each group). The osteotomy site was prepared by one operator following the manufacturer's instructions, using limiting and non-limiting surgical guides. Temperature changes were recorded during implant bed preparation using thermocouples that fit into 7 mm-horizontal channels at two different depths (Coronally) and (Apically) at 1 mm distance from the osteotomy site. The data were tested for homogeneity of variances using Levene's test, then data were analyzed using an Independent sample t-test and the significance level was set at P ≤ 0.05. RESULTS: The mean temperature rise for all samples was 0.55 °C. The mean temperature rises for the limiting and non-limiting surgical guides were 0.80 °C and 0.33 °C respectively. There was a statistically significant difference in temperature rise between the limiting and non-limiting surgical guides (P = 0.008). In relation to position of temperature recording (coronal vs. apical), there was no significant difference (P > 0.05). No significant difference was noted between the two groups at cancellous bone level (P = 0.68), but the difference was significant at cortical bone level (P = 0.036). CONCLUSION: Limiting surgical guides showed higher readings than non-limiting. However, for both techniques, temperature rise was not significant clinically and within a safe range.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。