"Comparing the effectiveness, acceptability and oral hygiene status between vacuum formed retainer and Begg's retainer": a pilot study

“真空成型保持器与贝格氏保持器的有效性、接受度和口腔卫生状况比较”:一项初步研究

阅读:1

Abstract

BACKGROUND: Recently, Vacuum formed retainers (VFRs) are preferred as an Orthodontic retention appliance over conventional Begg's retainers. Very few studies have been conducted between VFRs and Begg's retainers. Hence, this study aims at assessing the effectiveness, oral hygiene and acceptability between VFRs and Begg's retainers with a follow up period of 1 year. METHODS: Eighty patients who completed fixed Orthodontic treatment were included. Retainers were delivered on the same day of debonding. Retainer 1/ R1 stands for VFRs and Retainer 2/ R2 stands for Begg's retainers. The retainers were randomly allocated to both the arches. 40 VFRs and Begg's retainers in maxillary and mandibular arch were given respectively. Effectiveness, oral hygiene condition were performed at T(0) (After debonding), T(1) (3 months after using retainers), T(2) (6 months after using retainers), T(3) (9 months after using retainers), T(4) (12 months after using retainers) follow up stages, except the feedback form and the breakage of retainers that were filled at T(4) stage. RESULTS: Both R(1) and R(2) retainers showed improvement in teeth alignment in both the arches at follow up stages. Interproximal contacts in maxillary and mandibular arch with VFRs and Begg's retainers improved to 77.5% and 82.5% respectively. Considering the marginal ridge, Begg's retainers and VFRs showed 95%, 55% increased proportion at T(4) respectively (p < 0.05). Patients wearing Beggs's retainers had significantly better (p < 0.05) oral hygiene status. Significant differences were observed with Begg's retainers in teeth biting, whereas no significant difference was found with fitting of appliance (p = 0.180) and gingival irritation (p = 1.000). VFRs were well accepted aesthetically that was significant. Retainers were prone to breakage but was not significant (p = 0.162). CONCLUSION: Begg's wrap around retainers maintain good oral hygiene, improve the teeth alignment, interproximal contact and marginal ridges post Orthodontic treatment with better fitting of the appliance. VFRs are also preferred as they are good in maintaining proper teeth alignment with progressive improvement in the interproximal contacts and are aesthetically pleasing.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。