Mechanical activation with Easy Clean device enhanced organic tissue removal from simulated internal root resorption in a laboratory evaluation

在实验室评估中,使用易清洁装置进行机械激活可增强模拟根内吸收过程中有机组织的去除。

阅读:1

Abstract

BACKGROUND: Considering the irregular shape of the root canal, removing inflamed pulp and granulation tissue completely from internal resorption cavities during chemomechanical preparation can be challenging. This study aimed to evaluate the effectiveness of passive ultrasonic irrigation (PUI) compared to mechanical activation with Easy Clean in the removal of organic tissue from simulated areas of internal root resorption. METHODS: The root canals of 72 extracted single-rooted teeth with oval canals were instrumented with Reciproc R25 instruments. After root canal preparations, the specimens were split longitudinally, and semicircular cavities were prepared using a round bur on each half of the roots. Samples obtained from bovine muscle tissue were weighed and adapted into semicircular cavities. The roots were reassembled and joined, and the teeth were divided into six groups (n = 12) according to the irrigation protocol: Sodium hypochlorite (NaOCl) without activation; NaOCl + PUI; NaOCl + Easy Clean; distilled water without activation; distilled water + PUI; and distilled water + Easy Clean. After irrigation protocols, the teeth were disassembled, and the remaining organic tissue was weighed. Data were analyzed by two-way ANOVA and Tukey's post hoc test (p < 0.05). RESULTS: None of the experimental protocols totally removed the bovine tissue from simulated cavities. Tissue weight reduction was significantly affected by the activation method (p < 0.05) and by irrigation solution (p < 0.05). Groups with NaOCl irrigation presented higher tissue weight loss when compared to distilled water, for all irrigation methods (p < 0.05). The use of Easy Clean resulted in the greatest tissue weight loss (42.0%-Distilled water/45.5%- NaOCl) compared to those of PUI (33.3%-Distilled water/37.7%- NaOCl) and no activation (33.4%-Distilled water/38.8%- NaOCl) (p < 0.05). However, no differences were observed between PUI and no activation groups (p > 0.05). CONCLUSIONS: Mechanical activation with Easy Clean enhanced organic tissue removal from simulated internal resorption more effectively than PUI. Easy Clean for agitation of the irrigating solution is effective in removing simulated organic tissues from artificial internal resorption cavities, being an alternative to the use of PUI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。