Iontophoresis effects of two-step self-etch and total-etch systems on dentin permeability and sealing of composite restoration under simulated pulpal pressure

离子导入法研究两步自酸蚀和全酸蚀系统对模拟牙髓压力下牙本质渗透性和复合树脂修复体封闭性的影响

阅读:1

Abstract

BACKGROUND: Studies demonstrated the bond strength enhancement and the decrease in degradation of the adhesive interface after applying either self-etch adhesives or two-step, etch-and-rinse adhesives under an electric field. However, the presence of dentinal fluid driven by the pulpal pressure in vivo is a profounding factor affecting both the sealing ability and bond strength of adhesives. This study aimed to evaluate the effect of three-step etch-and-rinse and two-step self-etch adhesives when applied with iontophoresis under simulated pulpal pressure on the permeability of dentin, resin infiltration, and the sealing ability of resin composite. METHODS: The experiments were done on 32 recently extracted premolars, randomly assigned into four groups (n = 8) according to two adhesive systems (SBMP and SE), applied following the manufacturer's instructions (control) for two groups or with iontophoresis for the others (SBMPi and SEi). For the iontophoresis, the anodal current was applied at 75 μA for 20 s through the cavity electrode during the bond. The fluid flow rate of dentin was recorded after cavity preparation (smear-layer-covered dentin; T1), bonding (T2), and composite restoration (T3) during the maintained pulpal pressure of 20 mm Hg. The flow rates were expressed as a percentage relative to the initial smear-layer-covered value for each specimen. Results were analyzed using repeated measures ANOVA. Scanning electron microscopy (SEM) was performed to observe the resin/dentin interface. RESULTS: There were no significant increases in the mean flow rates from T1 to T3 in the SBMP (P = 0.355), while these changes in the SE were significant between T1 (100%) and T2 (166.77%) and T1 and T3 (221.16%) (P = 0.002; one-way RM ANOVA; Holm-Sidak test). For the iontophoresis groups, the mean flow rates decreased significantly from T1 to T2 and T1 to T3 of both SBMPi (T2 = 86.43, and T3 = 79.53; P < 0.001) and SEi groups (T2 = 87.96, and T3 = 81.48; P = 0.004). The iontophoresis of both adhesives produced the optimal resin infiltration with improved quality of the hybrid layer and resin tags. CONCLUSIONS: SBMP bonded with or without iontophoresis performed better sealing ability than SE under the same condition. Both adhesives applied with anodal iontophoresis significantly decreased the dentin permeability, contributing to the improved resin infiltration.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。