Comparison between two cell collecting methods for liquid-based brush biopsies: a consecutive and retrospective study

两种液基刷取活检细胞采集方法的比较:一项连续性和回顾性研究

阅读:1

Abstract

BACKGROUND: This study compares two different cell collectors, the Orcellex Brush (rigid brush) and the Cytobrush GT (nylon brush), using liquid-based cytology. A comparison of their obtainment procedures was also considered. The aim was to determine the diagnostic accuracy for detection of malignancy in oral brush biopsies. PICO-Statement: In this consecutive and retrospective study we had as population of interests, patients with oral lesions, the intervention was the brush biopsy with two different cell collectors and the control was healthy oral mucosa. The outcome of the study was to compare both cell collectors. METHODS: From 2009 to 2018, 2018 patients with oral lesions were studied using the nylon brush (666 cases) and rigid brush (1352 cases). In the first cohort five smears per patient were taken with the nylon brush, while each patient received one smear with the rigid brush in the second cohort. These were further processed in a liquid-based procedure. Cytological evaluations were categorised into 'negative', which were considered as negative, whereas 'doubtful', 'suspicious' and 'positive' cytological results were overall considered as positive for malignancy in comparison to the final histological diagnoses. Additionally, the clinical expenditure for each collector was estimated. RESULTS: 2018 clinically and histologically proven diagnoses were established, including 181 cases of squamous cell carcinomas, 524 lichen, 454 leukoplakias, 34 erythroplakias and 825 other benign lesions. The sensitivity and specificity of the nylon brush was 93.8% (95% CI 91.6-95.5%) and 94.2% (95% CI 91.8-95.5%) respectively, whereas it was 95.6% (95% CI 94.4-96.6%) and 84.9% (95% CI 83.8-87.5%) for the rigid brush. The temporal advantage using the plastic brushes was 4×  higher in comparison to the nylon brush. The risk suffering from a malignant oral lesion when the result of the brushes was positive, suspicious, or doubtful was significantly high for both tests (nylon brush OR: 246.3; rigid brush OR: 121.5). CONCLUSIONS: Both systems have a similar sensitivity, although only the rigid brush achieved a satisfactory specificity. Additional methods, such as DNA image cytometry, should also be considered to improve the specificity. Furthermore, the rigid brush proved to be more effective at taking a sufficient number of cells, whilst also being quicker and presenting less stress for the patient.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。