Patient satisfaction and oral health-related quality of life 10 years after implant placement

种植体植入后10年的患者满意度和口腔健康相关生活质量

阅读:1

Abstract

BACKGROUND: Implant survival and implant success (freedom of biologic complications) are important factors in assessing the success of implant therapy. However, these factors are not the only determinants. Patients' satisfaction also plays a very important role in daily practice. Therefore, the aim of this study was to assess patients' satisfaction regarding function (phonetics, chewing comfort, stability, cleanability) and aesthetics in patients treated with XiVE and Frialite implants in a private periodontal practice ten years after implant placement. Furthermore, oral health-related quality of life (OHRQoL) was evaluated. METHODS: Patient-reported outcome measures (PROMs) regarding overall satisfaction, phonetics, chewing comfort, stability, cleanability, and aesthetics were examined on a Visual Analog Scale (VAS) 10 years ± 6 months after implant placement in a cross-sectional survey. OHRQoL and psychological impact were assessed via the Oral Health Impact Profile (OHIP) and Psychosocial Impact of Dental Aesthetics Questionnaire (PIDAQ). Potential influence of patient-related factors (age, gender, smoking, peri-implantitis, implant position, type of restoration) on VAS, OHRQoL and PIDAQ were investigated using regression analyses. RESULTS: High satisfaction with implant-supported restorations was seen in all 95 patients ten years after implant placement. Mean VAS-score for general satisfaction with implant-supported restoration was 93.0% (SD ± 9.4, median: 96.3%, range 50.0-100%). Mean OHIP score was 11.3 (SD ± 10.8, median: 9.0, range 0-45), mean PIDAQ score 20.5 (SD ± 11.37, median: 17.0, range 0-52). A slight tendency that presence of a moderate/severe peri-implantitis lowers satisfaction could be detected (overall satisfaction: ordinal, p = 0.012, VAS, p = 0.026). Also, the factors age, implant position and type of restoration might have an impact on patient's satisfaction. CONCLUSIONS: Patients restored with mostly fixed implant-supported restorations showed a very high patient satisfaction regarding function and aesthetics 10-year after implant placement. The presence of a moderate/severe peri-implantitis showed a slight tendency for influencing patient satisfaction. Due to the cross-sectional design results have to be interpreted with care.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。