The accuracy and stability of the maxillary position after orthognathic surgery using a novel computer-aided surgical simulation system

利用新型计算机辅助手术模拟系统评估正颌手术后上颌位置的准确性和稳定性

阅读:1

Abstract

BACKGROUND: Many reports have been published on orthognathic surgery (OGS) using computer-aided surgical simulation (CASS). The purpose of this study was to evaluate the accuracy of the maxillary repositioning and the stability of the maxilla in patients who underwent OGS using a newly developed CASS program, a customized osteotomy guide, and a customized miniplate. METHODS: Thirteen patients who underwent OGS from 2015 to 2017 were included. All patients underwent a bimaxillary operation. First, a skull-dentition hybrid 3D image was rendered by merging the cone beam computed tomography (CBCT) images with the dentition scan file. After virtual surgery (VS) using the FaceGide® program, patient-customized osteotomy guides and miniplates were then fabricated and used in the actual operation. To compare the VS with the actual surgery and postoperative skeletal changes, each reference point marked on the image was compared before the operation (T0) and three days (T1), four months (T2), and a year (T3) after the operation, and with the VS (Tv). The differences between ΔTv (Tv-T0) and ΔT1 (T1-T0) were statistically compared using tooth-based reference points. The superimposed images of Tv and T1 were also investigated at eight bone-based reference points. The differences between the reference points of the bone surface were examined to evaluate the stability of the miniplate on the maxilla over time. RESULTS: None of the patients experienced complications. There were no significant differences between the reference points based on the cusp tip between ΔTv and ΔT1 (p > 0.01). Additionally, there were no significant differences between the Tv and T1 values of the bone surface (p > 0.01). The mean difference in the bone surface between Tv and T1 was 1.01 ± 0.3 mm. Regarding the stability of the miniplate, there were no significant differences between the groups. The difference in the bone surface between T1 and T3 was - 0.37 ± 0.29 mm. CONCLUSIONS: VS was performed using the FaceGide® program, and customized materials produced based on the VS were applied in actual OGS. The maxilla was repositioned in almost the same manner as in the VSP plan, and the maxillary position remained stable for a year.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。