Epidural spread of surgical site infection from spinal cord stimulation trial

脊髓刺激试验中手术部位感染硬膜外扩散

阅读:2

Abstract

We present a case of deep surgical site infection (SSI) at a spinal cord stimulator (SCS) trial implantation site, resulting from an allergic reaction to an unknown agent. A 38-year-old female with complex regional pain syndrome began an SCS trial, noting 100% pain relief for 5 days. Fluid drainage from the surgical site was reported on POD6 and trial leads were removed the following day. The patient was hospitalized with sepsis. Blood cultures revealed Staphylococcus aureus. MRIs showed skin breakdown and cellulitis of the paraspinal musculature extending into the epidural space. The patient was maintained with antibiotics and rigorous wound care for 9 days and the surgical site infection resolved. The patient proceeded to SCS implantation, and reported good pain relief with the implanted device.