Influence of plasma collection tubes on N-glycome in human blood samples

血浆采集管对人血样本中N-糖组的影响

阅读:1

Abstract

BACKGROUND AND AIMS: Quantitative analysis of plasma N-glycome is a promising method for identifying disease biomarkers. This study aimed to investigate the impact of using blood collection tubes with different anticoagulants on plasma N-glycome. MATERIALS AND METHODS: We used a robust mass spectrometry method to profile plasma N-glycomes in two cohorts of healthy volunteers (cohort 1, n = 16; cohort 2, n = 53). The influence of three commonly used blood collection tubes on fully characterized N-glycomic profiles were explored. RESULTS: Principal component analysis revealed distinct clustering of blood samples based on the collection tubes. Pairwise comparisons demonstrated significant differences between EDTA and heparin plasma in 55 out of 82 quantified N-glycan traits, and between EDTA and citrate plasma in 62 out of 82 traits. These differences encompassed various N-glycan features, including glycan type, sialylation, galactosylation, fucosylation, and bisection. Trends in N-glycan variations in citrate and heparin plasma were largely consistent compared to EDTA plasma. In correlation analysis (EDTA vs. heparin; EDTA vs. citrate), Pearson's correlation coefficients were consistently higher than 0.7 for the majority of N-glycan traits. CONCLUSION: Sample matrix variations impact plasma N-glycome measurements. Caution is crucial when comparing samples from different plasma collection tubes in glycomics projects.