Can tibial tantalum cones eventually eliminate the adjuvant use of metallic augments for AORI type 2B/3 metaphyseal defects??-A novel surgical technique and case series

胫骨钽锥最终能否取代AORI 2B/3型干骺端缺损的辅助金属植入物?——一种新型手术技术及病例系列研究

阅读:1

Abstract

BACKGROUND: For extensive metaphyseal defects, the use of tantalum cones is usually combined with adjuvant stems which may be cemented/cementless and metallic bone augments for additional stability. A Tibial baseplate-Cone construct with proud tibial cones and without metallic augments has been described for AORI type 2B/3 tibial defects. METHODS: A case series analysis of 6 patients with AORI type 3 defects treated with unstepped proud Tantalum tibial metaphyseal cones without metallic wedges/full width augments. A follow-up analysis done with clinico-radiographic interpretation. RESULTS: 100% osteointegration noted in final radiographs of all patients at an average follow-up of 4.1 years. Preoperative average ROM/KSS of 75/49 improved to postoperative ROM/KSS of 104/79. Outcomes were interpreted as excellent in 50% of cases and good in the remaining 50%. CONCLUSION: The "Tibial base plate-cone without augments (BCCA)"type of a construct may offer a valid long term advantage over the Tibial base plate-Augment-Cone combination in massive tibial bone defects. Simply building up the tantalum cone to the native joint line position by increasing cone height can exclude use of augments or wedges.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。