Risk Assessment After a Severe Hospital-Acquired Infection Associated With Carbapenemase-Producing Pseudomonas aeruginosa

与产碳青霉烯酶铜绿假单胞菌相关的严重医院获得性感染后的风险评估

阅读:1

Abstract

IMPORTANCE: Resistance of gram-negative bacilli to carbapenems is rapidly emerging worldwide. In 2016, the World Health Organization defined the hospital-built environment as a core component of infection prevention and control programs. The hospital-built environment has recently been reported as a source for outbreaks and sporadic transmission events of carbapenemase-producing gram-negative bacilli from the environment to patients. OBJECTIVE: To assess risk after the identification of an unexpected, severe, and lethal hospital-acquired infection caused by carbapenemase-producing Pseudomonas aeruginosa in a carbapenemase-low endemic setting. DESIGN, SETTINGS, AND PARTICIPANTS: A case series study in which a risk assessment was performed on all 11 patients admitted to the combined cardiothoracic surgery and pulmonary diseases ward and the hospital-built environment in the Radboud University Medical Center, the Netherlands, in February 2018. EXPOSURES: Water and aerosols containing carbapenemase-producing (Verona integron-mediated metallo-β-lactamase [VIM]) P aeruginosa. MAIN OUTCOMES AND MEASURES: Colonization and/or infection of patients and/or contamination of the environment after the detection of 1 patient infected with carbapenemase-producing (VIM) P aeruginosa. RESULTS: A total of 5 men (age range, 60-84 years) and 6 women (age range, 55-74 years) were admitted to the combined cardiothoracic surgery and pulmonary diseases ward. The risk assessment was performed after carbapenemase-producing (VIM) P aeruginosa was unexpectedly detected in a man in his early 60s, who had undergone a left-sided pneumonectomy and adjuvant radiotherapy. No additional cases (colonization or infection) of carbapenemase-producing (VIM) P aeruginosa were detected. Plausible transmission of carbapenemase-producing P aeruginosa from the hospital environment to the patient via the air was confirmed by whole-genome sequencing, which proved the relation of Pseudomonas strains from the patient, the shower drains in 8 patient rooms, 1 sink, and an air sample. CONCLUSIONS AND RELEVANCE: This study suggests that rethinking the hospital-built environment, including shower drains and the sewage system, will be crucial for the prevention of severe and potential lethal hospital-acquired infections.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。