Attention 3D UNET for dose distribution prediction of high-dose-rate brachytherapy of cervical cancer: Intracavitary applicators

针对宫颈癌高剂量率近距离放射治疗剂量分布预测的3D UNET模型:腔内施源器

阅读:1

Abstract

BACKGROUND: Formulating a clinically acceptable plan within the time-constrained clinical setting of brachytherapy poses challenges to clinicians. Deep learning based dose prediction methods have shown favorable solutions for enhancing efficiency, but development has primarily been on external beam radiation therapy. Thus, there is a need for translation to brachytherapy. PURPOSE: This study proposes a dose prediction model utilizing an attention-gating mechanism and a 3D UNET for cervical cancer high-dose-rate intracavitary brachytherapy treatment planning with tandem-and-ovoid/ring applicators. METHODS: A multi-institutional data set consisting of 77 retrospective clinical brachytherapy plans was utilized in this study. The data were preprocessed and augmented to increase the number of plans to 252. A 3D UNET architecture with attention gates was constructed and trained for mapping the contour information to dose distribution. The trained model was evaluated on a testing data set using various metrics, including dose statistics and dose-volume indices. We also trained a baseline UNET model for a fair comparison. RESULTS: The attention-gated 3D UNET model exhibited competitive accuracy in predicting dose distributions similar to the ground truth. The average values of the mean absolute errors were 0.46 ± 11.71 Gy (vs. 0.47 ± 9.16 Gy for a baseline UNET) in CTV(HR), 0.55 ± 0.67 Gy (vs. 0.70 ± 1.54 Gy for a baseline UNET) in bladder, 0.42 ± 0.46 Gy (vs. 0.49 ± 1.34 Gy for a baseline UNET) in rectum, and 0.31 ± 0.65 Gy (vs. 0.20 ± 3.76 Gy for a baseline UNET) in sigmoid. Our results showed that the mean individual differences in ΔD(2cc) for bladder, rectum, and sigmoid were 0.38 ± 1.19 (p = 0.50), 0.43 ± 0.71 (p = 0.41), and -0.47 ± 0.79 (p = 0.30) Gy, respectively. Similarly, the mean individual differences in ΔD(1cc) for bladder, rectum, and sigmoid were 0.09 ± 1.21 (p = 0.36), 0.20 ± 0.95 (p = 0.24), and -0.21 ± 0.59 (p = 0.30) Gy. The mean individual differences for ΔD(90), ΔV(100%), ΔV(150%), and ΔV(200%) of the CTV(HR) were -0.45 ± 2.42 (p = 0.26) Gy, 0.55 ± 9.42% (p = 0.78), 0.82 ± 4.21% (p = 0.81), and -0.80 ± 10.48% (p = 0.36), respectively. The model requires less than 5 s to predict a full 3D dose distribution for a new patient plan. CONCLUSION: Attention-gated 3D UNET revealed a promising capability in predicting voxel-wise dose distributions compared to 3D UNET. This model could be deployed for clinical use to predict 3D dose distributions for near real-time decision-making before planning, quality assurance, and guiding future automated planning, making the current workflow more efficient.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。