Quality comparison between three-dimensional T2-weighted SPACE and two-dimensional T2-weighted turbo spin echo magnetic resonance images for the brachytherapy planning evaluation of prostate and periprostatic anatomy

三维T2加权SPACE序列与二维T2加权快速自旋回波磁共振图像在近距离放射治疗计划评估中对前列腺及前列腺周围解剖结构的评价质量比较

阅读:1

Abstract

PURPOSE: The purpose of this study was to compare an isotropic three-dimensional (3D) T2-weighted sequence sampling perfection with application-optimized contrasts by using flip angle evolution (SPACE) with an axial two-dimensional T2-weighted turbo spin echo (TSE) sequence with regard to overall image quality and the delineation of normal prostate and periprostatic anatomy for low-dose-rate prostate cancer brachytherapy planning evaluation. METHODS AND MATERIALS: Patients (n = 69) with prostate cancer who had pelvic magnetic resonance imaging (MRI) for low-dose-rate brachytherapy treatment planning were included. Three radiologists independently assessed the visibility of nine anatomic structures on each sequence by using a 5-point scale and overall image quality by using a 4-point scale. The significance of the differences in diagnostic performance was tested with a Wilcoxon signed rank test. RESULTS: No significant intersequence differences were found for most (7/9) anatomical structures and overall image quality. The mean scores for visibility of anatomical structures on the 3D SPACE and 2D TSE sequences, respectively, were as follows: the zonal anatomy (3.7; 3.9, p = 0.05), prostate capsule (3.9; 4.0, p = 0.08), neurovascular bundle (2.9; 2.9, p = 0.9), rectoprostatic angle (3.8; 3.8, p = 0.35), rectum (4.2; 4.3, p = 0.26), urethra (3.8; 3.9, p = 0.12), urinary bladder (4.6; 4.6, p = 0.61), and overall image quality (2.9; 2.9, p = 0.33). 3D SPACE was superior for delineation of the genitourinary diaphragm (3.8; 3.6, p = 0.003), whereas 2D TSE was superior for delineation of the seminal vesicles (3.5; 4.0, p < 0.0001). CONCLUSIONS: Anatomic delineation of the prostatic and periprostatic anatomy provided by the 3D SPACE sequence is as robust in quality as that provided by a conventional 2D TSE sequence with superior delineation of the genitourinary diaphragm. For MRI-based brachytherapy treatment planning, the 3D SPACE sequence with subcentimeter isotropic resolution can replace the 2D TSE sequence and be incorporated into standard MRI protocols.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。