Statistical Analysis of Interfraction Dose Variations of High-Risk Clinical Target Volume and Organs at Risk for Cervical Cancer High-Dose-Rate Brachytherapy

宫颈癌高危临床靶区及危及器官分次剂量变化的统计分析(高剂量率近距离放射治疗)

阅读:1

Abstract

PURPOSE: High-dose-rate (HDR) brachytherapy for cervical cancer treatment includes significant uncertainties. The aim of this study was to quantify the interfraction dosimetric variation (IDV) of the high-risk clinical target volume (HRCTV) from the prescribed dose and the corresponding effect on organ-at-risk (OAR) dose based on a comprehensive statistical analysis. METHODS AND MATERIALS: Fifty patients with cervical cancer treated with high-dose-rate intracavity brachytherapy from October 2019 to December 2020 were retrospectively analyzed. The OARs of interest were the rectum, bladder, sigmoid, and bowel. The dosimetric parameters evaluated for all patients was the dose absorbed by 90% of the HRCTV ( D90 ) and the dose absorbed by 0.1 ( D0.1cc ) and 2 cm(3) ( D2cc ) of each respective OAR. The HRCTV variations were from the prescribed dose and the OAR variations were from the corresponding tolerance dose. Distribution fitting of the HRCTV variations was determined to quantify the IDV. Comparative statistics of the HRCTV variations with the OAR variations were conducted to determine correlations. RESULTS: The mean HRCTV variation from the prescribed dose was -2.53% ± 8.74%. The HRCTV variations and OAR variations showed moderate to weak linear correlations despite the variations being relative to each other, with the bladder D2cc having the strongest correlation. There was a 30.0% (±2.62%, 95% confidence interval) probability of underdosing the HRCTV (-5% variation from prescription) and a 23.3% (±2.62%, 95% confidence interval) probability of overdosing the HRCTV (+5% variation from prescription). This tendency to underdose the HRCTV was a consequence of HRCTV IDV not being normally distributed. CONCLUSIONS: HRCTV dosimetric variations and OAR variations were complexly correlated with the bladder D2cc having the strongest correlation. HRCTV IDV was best described as a left-skewed distribution that indicates a tendency of underdosing the HRCTV. The clinical significance of such dose variations is expected and will be further investigated.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。