Dosimetric analysis of radiation therapy oncology group 0321: the importance of urethral dose

放射治疗肿瘤组0321的剂量学分析:尿道剂量的重要性

阅读:1

Abstract

PURPOSE: Radiation Therapy Oncology Group 0321 is the first multi-institutional cooperative group high-dose-rate (HDR) prostate brachytherapy trial with complete digital brachytherapy dosimetry data. This is a descriptive report of the data and an analysis of toxicity. METHODS AND MATERIALS: Patients are treated with external beam radiation therapy at 45 Gy and 1 HDR implant with 19 Gy in 2 fractions. Implants are done with transrectal ultrasound guidance, and computed tomography (CT)-compatible nonmetallic catheters. HDR planning is done on ≤3-mm-thick CT slices. The "mean DVH" (dose-volume histogram) of the planning target volume (PTV), implanted volume (IP), and organs at risk are calculated. This includes the mean and standard deviation (SD) of the volume at 10-percentage-point intervals from 10% to 200% of the prescribed dose. The conformal index (COIN), homogeneity index (HI), catheters per implant, and patients per institution are calculated. Multivariate analysis and hazard ratios calculation of all the variables against reported grade ≥2 (G2+) genitourinary (GU) adverse events (Common Terminology Criteria for Adverse Events, version 3) are performed. RESULTS: Dosimetry data are based on 122 eligible patients from 14 institutions. The mean of PTV, IP, catheters per implant, and patients per institution are 54 cc, 63 cc, 19 and 9, respectively. The mean of %V100PTV, V80Bladder, V80Rectum, and V120Urethra were 94%, 0.40 cc, 0.15 cc, and 0.25 cc, respectively. There are too few G2+ gastrointestinal adverse event (GI AE) for correlative analysis; thus, the analysis has been performed on the more common G2+ GU AE. There are positive correlations noted between both acute and late G2+ GU AE and urethral dose at multiple levels. Positive correlations with late AE are seen with PTV and IP at high-dose levels. A negative correlation is seen between HI and acute AE. A higher patient accrual rate is associated with a lower rate of G2+ acute and late AE. CONCLUSIONS: Higher urethral dose, larger high-dose volumes, and lower dose homogeneity are associated with greater toxicities. A mean dose-volume histogram comparison at all dose levels should be used for quality control and future research comparison.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。