Review of Deep Learning Based Autosegmentation for Clinical Target Volume: Current Status and Future Directions

基于深度学习的临床靶区自动分割综述:现状与未来方向

阅读:4

Abstract

PURPOSE: Manual contour work for radiation treatment planning takes significant time to ensure volumes are accurately delineated. The use of artificial intelligence with deep learning based autosegmentation (DLAS) models has made itself known in recent years to alleviate this workload. It is used for organs at risk contouring with significant consistency in performance and time saving. The purpose of this study was to evaluate the performance of present published data for DLAS of clinical target volume (CTV) contours, identify areas of improvement, and discuss future directions. METHODS AND MATERIALS: A literature review was performed by using the key words "deep learning" AND ("segmentation" or "delineation") AND "clinical target volume" in an indexed search into PubMed. A total of 154 articles based on the search criteria were reviewed. The review considered the DLAS model used, disease site, targets contoured, guidelines used, and the overall performance. RESULTS: Of the 53 articles investigating DLAS of CTV, only 6 were published before 2020. Publications have increased in recent years, with 46 articles published between 2020 and 2023. The cervix (n = 19) and the prostate (n = 12) were studied most frequently. Most studies (n = 43) involved a single institution. Median sample size was 130 patients (range, 5-1052). The most common metrics used to measure DLAS performance were Dice similarity coefficient followed by Hausdorff distance. Dosimetric performance was seldom reported (n = 11). There was also variability in specific guidelines used (Radiation Therapy Oncology Group (RTOG), European Society for Therapeutic Radiology and Oncology (ESTRO), and others). DLAS models had good overall performance for contouring CTV volumes for multiple disease sites, with most studies showing Dice similarity coefficient values >0.7. DLAS models also delineated CTV volumes faster compared with manual contouring. However, some DLAS model contours still required at least minor edits, and future studies investigating DLAS of CTV volumes require improvement. CONCLUSIONS: DLAS demonstrates capability of completing CTV contour plans with increased efficiency and accuracy. However, most models are developed and validated by single institutions using guidelines followed by the developing institutions. Publications about DLAS of the CTV have increased in recent years. Future studies and DLAS models need to include larger data sets with different patient demographics, disease stages, validation in multi-institutional settings, and inclusion of dosimetric performance.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。