Concordance of FDG PET/CT metabolic tumour volume versus DW-MRI functional tumour volume with T2-weighted anatomical tumour volume in cervical cancer

FDG PET/CT代谢肿瘤体积与DW-MRI功能肿瘤体积及T2加权解剖肿瘤体积在宫颈癌中的一致性

阅读:1

Abstract

BACKGROUND: (18)F-fluoro-deoxyglucose positron emission tomography with computed tomography (FDG PET/CT) has been employed to define radiotherapy targets using a threshold based on the standardised uptake value (SUV), and has been described for use in cervical cancer. The aim of this study was to evaluate the concordance between the metabolic tumour volume (MTV) measured on FDG PET/CT and the anatomical tumour volume (ATV) measured on T2-weighted magnetic resonance imaging (T2W-MRI); and compared with the functional tumour volume (FTV) measured on diffusion-weighted MRI (DW-MRI) in cervical cancer, taking the T2W-ATV as gold standard. METHODS: Consecutive newly diagnosed cervical cancer patients who underwent FDG PET/CT and DW-MRI were retrospectively reviewed from June 2013 to July 2017. Volumes of interest was inserted to the focal hypermetabolic activity corresponding to the cervical tumour on FDG PET/CT with automated tumour contouring and manual adjustment, based on SUV 20%-80% thresholds of the maximum SUV (SUVmax) to define the MTV(20-80), with intervals of 5%. Tumour areas were manually delineated on T2W-MRI and multiplied by slice thickness to calculate the ATV. FTV were derived by manually delineating tumour area on ADC map, multiplied by the slice thickness to determine the FTV((manual)). Diffusion restricted areas was extracted from b0 and ADC map using K-means clustering to determine the FTV((semi-automated)). The ATVs, FTVs and the MTVs at different thresholds were compared using the mean and correlated using Pearson's product-moment correlation. RESULTS: Twenty-nine patients were evaluated (median age 52 years). Paired difference of mean between ATV and MTV was the closest and not statistically significant at MTV(30) (-2.9cm(3), -5.2%, p = 0.301). This was less than the differences between ATV and FTV((semi-automated)) (25.0cm(3), 45.1%, p < 0.001) and FTV((manual)) (11.2cm(3), 20.1%, p = 0.001). The correlation of MTV(30) with ATV was excellent (r = 0.968, p < 0.001) and better than that of the FTVs. CONCLUSIONS: Our study demonstrated that MTV(30) was the only parameter investigated with no statistically significant difference with ATV, had the least absolute difference from ATV, and showed excellent positive correlation with ATV, suggesting its superiority as a functional imaging modality when compared with DW-MRI and supporting its use as a surrogate for ATV for radiotherapy tumour contouring.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。