Are Trace Elements Provided for Children on Long-Term Parenteral Nutrition Adequate to Meet Their Needs?

长期肠外营养儿童所摄入的微量元素是否足以满足其需求?

阅读:1

Abstract

Background: We conducted a cross-sectional study to investigate whether children receiving long-term parenteral nutrition (LPN) are at risk of imbalances in selected trace elements. Methods: Serum levels of manganese, zinc, copper, selenium, and iodine were measured in 83 children on LPN and compared with 121 healthy controls. Children with signs of infection or elevated C-reactive protein levels were excluded. Elemental analysis was performed using inductively coupled plasma mass spectrometry (ICP-MS). Results: Manganese and copper levels were significantly lower in the study group compared with controls (p < 0.001) but remained within normal ranges. Iodine levels were also significantly lower in the study group (p < 0.05), though pediatric reference values are lacking. Zinc and selenium levels were significantly higher in the study group (p < 0.001), with median levels within normal ranges in both groups. Zinc, selenium, and iodine levels were higher in patients weighing ≤15 kg (p < 0.001, p < 0.001, p < 0.02). Conclusions: Serum concentrations of manganese, copper, and selenium in the study group remained within normal ranges, even though children weighing over 15 kg received doses below those recommended by scientific guidelines. An iodine intake below 1 μg/kg/day in patients weighing over 15 kg appears insufficient. Patients on LPN required a higher zinc intake than current recommendations.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。