Cellular Automaton Simulation of Corrosion in 347H Steel Exposed to Molten Solar Salt at Pilot-Plant Scale

利用元胞自动机模拟中试规模下347H钢在熔融太阳盐中的腐蚀行为

阅读:2

Abstract

The fast-paced depletion of fossil fuels and environmental concerns have intensified interest in renewable energies, with dispatchable solar energy emerging as a key alternative. Concentrated solar power (CSP) technology, utilizing thermal energy storage (TES) systems with molten salts at 560 °C, offers significant potential for large-scale energy generation. However, these extreme conditions pose challenges related to material corrosion, which is critical for maintaining the efficiency and lifespan of CSP. This research modeled the corrosion process of 347H stainless steel in molten solar salt (60% NaNO(3) + 40% KNO(3)) melted at 400 °C using a cellular automaton (CA) algorithm. The CA model simulated oxide growth under pilot-plant conditions in a lattice of 400 × 400 cells. SEM-EDS imaging compared the model with a mean squared error of 2%, corresponding to a corrosion layer of 4.25 µm after 168 h. The simulation applied von Neumann and Margolus neighborhoods for the ion movement and reaction rules, achieving a cell size of 0.125 µm and 10.08 s per iteration. This study demonstrates the CA model's effectiveness in replicating corrosion processes, offering a tool to optimize material performance in CSP systems. Additionally, continuing this investigation could contribute to the development of industrial applications, enabling the design of preventive strategies for large-scale operations.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。