Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Procedure for Endodontic Access Cavities: An in Vitro Study

计算机辅助动态导航与计算机辅助静态操作在根管治疗开髓洞术中的准确性比较:一项体外研究

阅读:1

Abstract

: Purpose: To analyze the accuracy of two computer-aided navigation techniques to guide the performance of endodontic access cavities compared with the conventional access procedure. MATERIALS AND METHODS: A total of 30 single-rooted anterior teeth were selected, which were randomly distributed into three study groups: Group A-guided performance of endodontic access cavities through computer-aided static navigation system (n = 10) (SN); Group B-guided performance of endodontic access cavities through computer-aided dynamic navigation system (n = 10) (DN); and Group C-manual (freehand) performance of endodontic access cavities (n = 10) (MN). The endodontic access cavities of the SN group were performed with a stereolithography template designed on 3D implant planning software, based on preoperative cone-beam computed tomography (CBCT) and a 3D extraoral surface scan, and endodontic access cavities of the DN group were planned and performed by the dynamic navigation system. After endodontic access cavities were performed, a second CBCT was done, and the degree of accuracy between the planned and performed endodontic access cavities was analyzed using therapeutic planning software and Student's t-test. RESULTS: Paired t-test revealed no statistically significant differences between SN and DN at the coronal (p = 0.6542), apical (p = 0.9144), or angular (p = 0.0724) level; however, statistically significant differences were observed between the two computer-aided navigation techniques and the MN group at the coronal (p < 0.0001), apical (p < 0.0001), and angular (p < 0.0001) level. CONCLUSION: Both computer-aided static and dynamic navigation procedures allowed accurate performance of endodontic access cavities.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。