Simultaneous intra-operative repair for inadvertent dural tear under posterior lumbar disk scope

在后路腰椎间盘镜手术中同时进行术中意外硬膜撕裂的修复

阅读:1

Abstract

OBJECTIVE: To introduce a microsurgical suture technique for repair of dural tear under posterior lumbar disk scope. METHODS: Micro endoscopic discectomy was performed on a 26-year-old male under local anesthesia. During the operation, an irregular tear of about 1.0 cm was inadvertently made in the dura.The cauda equina herniated through the tear with fluctuations and leakage of cerebrospinal fluid. The tear was successfully sutured with a 7/0 microsurgical thread which was held by small disk forceps in a parallel position. RESULTS: Once the repair had been performed, minor cerebrospinal fluid leakage persisted but there was no herniation of the cauda equina. The original planned operation was completed smoothly under posterior lumbar disk scope. CONCLUSION: The microsurgical suture technique for dural tear under posterior lumbar disk scope described here is simple and reliable.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。