Mechanical properties of the flexor digitorum profundus tendon attachment

指深屈肌腱附着点的机械特性

阅读:1

Abstract

The current study was performed to determine the strength and rigidity of the intact flexor digitorum profundus (FDP) tendon attachment and compare the rigidity at the attachment site to the rigidity within a more proximal part of the tendon. Eight cadaveric index fingers were tested to failure of the FDP tendon. Lines were drawn on each tendon with India ink stain at the position of the attachment to bone and 5 mm and 10 mm proximally. Each test was recorded using a high resolution video camera. A minimum of six images per test were used for analysis of tissue deformation. The centroid of each line was computationally identified to characterize the deformation of the tendon between the lines. Force vs. deformation curves were generated for the 5 mm region representing the tendon attachment and the 5 mm region adjacent to the attachment. Stiffness measurements were generated for each curve, and normalized by the initial length to determine the rigidity. The failure strength ranged from 263 N to 548 N, with rigidity values ranging from 2201 N/(mm/mm) to 8714 N/(mm/mm) and from 3459 N/(mm/mm) to 6414 N/(mm/mm) for the attachment and the tendon proximal to the attachment, respectively. The rigidity did not vary significantly between the attachment and proximal tendon based on a Wilcoxon signed rank test (p = 0.2). The measured strength and rigidity establish biomechanical properties for the FDP tendon attachment to bone.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。