Outcome of endoscopic transsphenoidal surgery for acromegaly: Comparison of using and not using the floor standing pneumatic powered endoscope-holder system

经蝶窦内镜手术治疗肢端肥大症的疗效:使用与不使用落地式气动内镜支架系统的比较

阅读:1

Abstract

INTRODUCTION: Endoscopic transsphenoidal surgery can be performed by two surgeons, including an endoscopist (PE/2S), and by a single surgeon with an endoscope-holder system (PE/1S + H). We analyzed the surgical outcome, and outcome predictors in acromegaly patients in endoscopic transsphenoidal surgery using floor standing pneumatic endoscope-holder system. METHODS: Endoscopic transsphenoidal surgery was performed with PE/1S+H (n = 51) and PE/2S (n = 20). Postoperative remission was evaluated by the 2010 consensus criteria for acromegaly. We compared the surgical results of PE/2S style and PE/1S+H style, and investigated the factors associated with favorable surgical outcomes. RESULTS: There was no difference in clinical background between the PE/2S and the PE/1S + H groups. The remission rates for PE/2S and PE/1S+H were 65.0% and 82.4%, respectively, with no significant difference (p = 0.128). In consecutive 71 cases, statistically useful predictors of remission were low preoperative growth hormone (GH) level (<12 ng/mL), low Knosp grade (0-2), and low revised Knosp grade (0-3A). In the conventional Knosp grade 0-2 and 3/4, the sensitivity was 0.76 and the specificity was 0.81. In the revised Knosp grade 0-3A and 3B/4, the sensitivity was 0.96 and the specificity was 0.44. CONCLUSION: The outcome of GH-producing pituitary neuroendocrine tumors surgically removed by PE/1S+H could be almost equivalent to that by PE/2S. Preoperative low GH level and Knosp grades, including revised Knosp grades, are useful preoperative predictors for surgical remission of acromegaly.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。