Direct Measurement of ATP7B Peptides Is Highly Effective in the Diagnosis of Wilson Disease

直接测量 ATP7B 肽对威尔逊病的诊断非常有效

阅读:5
作者:Christopher J Collins, Fan Yi, Remwilyn Dayuha, Phi Duong, Simon Horslen, Michelle Camarata, Ayse K Coskun, Roderick H J Houwen, Tudor L Pop, Heinz Zoller, Han-Wook Yoo, Sung Won Jung, Karl H Weiss, Michael L Schilsky, Peter Ferenci, Si Houn Hahn

Aims

Both existing clinical criteria and genetic testing have significant limitations for the diagnosis of Wilson disease (WD), often creating ambiguities in patient identification and leading to delayed diagnosis and ineffective management. ATP7B protein concentration, indicated by direct measurement of surrogate peptides from patient dried blood spot samples, could provide primary evidence of WD. ATP7B concentrations were measured in patient samples from diverse backgrounds, diagnostic potential is determined, and

Background & aims

Both existing clinical criteria and genetic testing have significant limitations for the diagnosis of Wilson disease (WD), often creating ambiguities in patient identification and leading to delayed diagnosis and ineffective management. ATP7B protein concentration, indicated by direct measurement of surrogate peptides from patient dried blood spot samples, could provide primary evidence of WD. ATP7B concentrations were measured in patient samples from diverse backgrounds, diagnostic potential is determined, and

Conclusions

Quantification of ATP7B peptide effectively identified WD patients in 92.1% of presented cases and reduced ambiguities resulting from ceruloplasmin and genetic analysis. Clarity is brought to patients with ambiguous genetic results, significantly aiding in noninvasive diagnosis. A proposed diagnostic score and algorithm incorporating ATP7B peptide concentrations can be rapidly diagnostic and supplemental to current Leipzig scoring systems.

Methods

Two hundred and sixty-four samples from biorepositories at 3 international and 2 domestic academic centers and 150 normal controls were obtained after Institutional Review Board approval. Genetically or clinically confirmed WD patients with a Leipzig score >3 and obligate heterozygote (carriers) from affected family members were included. ATP7B peptide measurements were made by immunoaffinity enrichment mass spectrometry.

Results

Two ATP7B peptides were used to measure ATP7B protein concentration. Receiver operating characteristics curve analysis generates an area under the curve of 0.98. ATP7B peptide analysis of the sequence ATP7B 887 was found to have a sensitivity of 91.2%, specificity of 98.1%, positive predictive value of 98.0%, and a negative predictive value of 91.5%. In patients with normal ceruloplasmin concentrations (>20 mg/dL), 14 of 16 (87.5%) were ATP7B-deficient. In patients without clear genetic results, 94% were ATP7B-deficient. Conclusions: Quantification of ATP7B peptide effectively identified WD patients in 92.1% of presented cases and reduced ambiguities resulting from ceruloplasmin and genetic analysis. Clarity is brought to patients with ambiguous genetic results, significantly aiding in noninvasive diagnosis. A proposed diagnostic score and algorithm incorporating ATP7B peptide concentrations can be rapidly diagnostic and supplemental to current Leipzig scoring systems.