Development and validation of an HPLC method to determine the stability of fentanyl citrate and bupivacaine hydrochloride mixtures in infusion solutions

开发并验证 HPLC 方法以确定输液溶液中柠檬酸芬太尼和盐酸布比卡因混合物的稳定性

阅读:14
作者:Mikołaj Piekarski, Anna Jelin'ska, Kamil Szymczak

Background

The use of a combination of different drugs in postoperative analgesia extends the time of analgesia, makes it more efficient and allows the use of lower drug doses, which leads to less risk of side effects and drug dependence. The

Methods

AFTER OPTIMISATION, THE HPLC METHOD PARAMETERS WERE AS FOLLOWS: LiChrospher 100 CN, 250×4 mm (10 µm) column; mobile phase: mixture of acetonitrile and phosphate buffer at pH 2.8 (3:7, V/V) with addition of 0.08 g/l potassium chloride; flow rate: 1.5 ml/min; column temperature: 30°C; spectrophotometric detection at 210 nm. Development of the method involved checking the impact of acetonitrile and KCl concentrations in the mobile phase and choosing the internal standard. Method validation included determining the specificity of the method, its accuracy, linearity, precision, repeatability, limits of detection and quantification.

Results

The retention times of bupivacaine hydrochloride, fentanyl citrate and procaine hydrochloride, used as an internal standard, were approximately 10 min, 15 min and 5 min, respectively. Method validation confirmed its selectivity, accuracy and precision. The average values of the variation and accuracy coefficients were 0.70% and 99.02% for bupivacaine hydrochloride, and 1.76% and 104.53% for fentanyl citrate. The intermediate precision values were 1.25% for bupivacaine hydrochloride and 1.52% for fentanyl citrate.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。