Serial Measurements of Refractive Index, Glucose and Protein to Assess Gastric Liquid Nutrient Transport-A Proof-of-Principal Study

通过连续测量折射率、葡萄糖和蛋白质来评估胃液营养物质转运——一项原理验证研究

阅读:1

Abstract

Delayed gastric emptying contributes to complications as aspiration or malnutrition. Among patients suffering from acute neurological diseases, motility disorders are prevalent but poorly understood. Thus, methods to measure gastric emptying are required to allow for appropriate adaptions of individual enteral nutrition algorithms. For enterally fed patients repetitive concentration measurements of gastric content have been proposed to assess gastric emptying. This approach can be used to calculate the gastric residual volume (GRV) and transport of nutrition formula (NF), but it has not yet been implemented in clinical routine. The aim of this study was to investigate whether refractometry or other likewise straightforward analytical approaches produce the best results under in vitro conditions mimicking the gastric milieu. We measured NF in different known concentrations, either diluted in water or in simulated gastric fluid (SGF), with each of the following methods: refractometer, handheld glucose meter, and Bradford protein assay. Then, in enterally fed patients suffering from acute neurological disease, we calculated GRVs and nutrition transport and tested possible associations with clinical parameters. In water dilution experiments, NF concentrations could be assessed with the readout parameters of all three methods. Refractometry yielded the most precise results over the broadest range of concentrations and was biased least by the presence of SGF (detection range for Fresubin original fibre, given as volume concentration/normalized error of regression slope after incubation with water or SGF: 0-100 vs. 0-100%/0.5 vs. 3.9%; glucose-measurement: 5-100 vs. 25-100%/7.9 vs. 6.1%; Bradford-assay: 0-100 vs. 0-100%/7.8 vs. 15.7%). Out of 28 enterally fed patients, we calculated significant slower nutrition transport in patients with higher blood glucose (Rho -0.391; p = 0.039) and in patients who received high-dose sufentanil (Rho -0.514; p = 0.005). Also, the calculated nutrition transport could distinguish patients with and without feeding intolerance (Median 6 vs. 17 ml/h; Mann-Whitney test: p = 0.002). The results of our study prove that serial refractometry is a suitable and cost-effective method to assess gastric emptying and to enhance research on gastrointestinal complications of stroke.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。