Relative Bioavailability of a Single 4-mg Dose of Somatropin Administered by Subcutaneous Injection or by Needle-free Device and Coadministered With the Growth Hormone Inhibitor Octreotide Acetate in Healthy Adult Subjects

健康成年受试者通过皮下注射或无针装置注射单剂量 4 毫克生长激素并与生长激素抑制剂醋酸奥曲肽共同给药的相对生物利用度

阅读:21
作者:Darin B Brimhall, Niclas Petri, Pina D'Angelo

Methods

In this randomized, single-dose, crossover study, healthy adults aged 18 to 35 years received single 4-mg doses of somatropin via a needle-free device or SC injection, along with octreotide to suppress endogenous growth hormone production. Blood samples were analyzed for serum somatropin and insulin-like growth factor-1 (IGF-1) concentrations over 24 hours after somatropin dosing. Pharmacokinetic and pharmacodynamic parameters were evaluated by using noncompartmental methods, and bioequivalence was determined based on ln transformation of the AUC0-24, AUC0-∞, Cmax, area under the effect-time curve from time 0 to 24 hours (AUEC0-24), and maximum effect concentration (Emax). Bioequivalence was concluded if the 90% CIs of the needle-free device compared with the SC injection, constructed by using the two 1-sided hypotheses at the α = 0.05 level, for these pharmacokinetic/pharmacodynamic parameters fell within the 80.00% to125.00% regulatory acceptance range. Findings: A total of 57 subjects completed both study periods and were included in the pharmacokinetic analyses. Point estimates (90% CIs) of the geometric mean ratio (needle-free device/SC injection) based on serum somatropin were 1.013 (0.987-1.040) for AUC0-24, 1.012 (0.986-1.038) for AUC0-∞, and 1.200 (1.137-1.267) for Cmax. For IGF-1, baseline-corrected point estimates (90% CIs) were 0.901 (0.818-0.993) for AUEC0-24 and 0.867 (0.795-0.946) for Emax. Non-baseline-corrected values were 0.978 (0.953-1.004) for AUEC0-24 and 0.953 (0.923-0.984) for Emax. Both treatments were well tolerated; blood glucose levels increased in nearly all subjects (98.3%). All adverse events were mild and resolved spontaneously within 24 hours. Implications: Bioequivalence was shown for a single 4-mg dose of somatropin delivered by using a needle-free device compared with SC injection based on ln-transformed AUC0-24 and AUC0-∞ but not ln-transformed Cmax.

Purpose

Somatropin, used to treat growth hormone deficiency, has been traditionally administered by subcutaneous (SC) injection with needle and syringe. Needle-free devices offer ease of administration and may improve adherence and outcomes. This study evaluated the relative bioavailability of somatropin delivered with a needle-free device compared with traditional SC injection.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。