In Vivo Study of Local and Systemic Responses to Clinical Use of Mg-1Ca Bioresorbable Orthopedic Implants

Mg-1Ca生物可吸收骨科植入物临床应用后局部和全身反应的体内研究

阅读:1

Abstract

(1) Background: Resorbable Mg-based implants represent a new direction in orthopedic surgery but have some drawbacks, such as their rapid biodegradation and increased rate of corrosion. Some in vitro studies hypothesized that tissue necrosis, incision dehiscence, risk of gas embolization in vital organs, interference with coagulation processes, and trophocyte viability impairment can occur. (2) Methods: We conducted an in vivo study on ten rabbit cases, in two groups; group one, consisting of six cases, received cylindrical implants of Mg-1Ca alloy in tibial intramedullary bone tissue. Group two, consisting of four cases, received Mg-1Ca parallelepiped implants, in the thigh muscular tissue. We recorded and compared weight (preoperatively and at 2, 4, and 6 weeks postoperatively), complete blood count, serum electrolytes, liver and kidney functional markers, and coagulation parameters, prior to and at 6 weeks after surgery. Local evolution was assessed radiologically and with tissue biopsies with complete pathology analysis. (3) Results: All biological markers and clinical evolution were favorable, showing good integration of the implants with none of the local or systemic signs of degradation. (4) Conclusions: Our study shows that the clinical use of Mg-1Ca bioresorbable alloys can be safe as none of the cited local or systemic complications have been identified.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。