Assessment of Antitachycardia Pacing in Primary Prevention Patients: The APPRAISE ATP Randomized Clinical Trial

评估一级预防患者抗心动过速起搏:APPRAISE ATP随机临床试验

阅读:1

Abstract

IMPORTANCE: The emergence of novel programming guidelines that reduce premature and inappropriate therapies along with the availability of new implantable cardioverter-defibrillator (ICD) technologies lacking traditional endocardial antitachycardia pacing (ATP) capabilities requires the reevaluation of ATP as a first strategy in terminating fast ventricular tachycardias (VTs) in primary prevention ICD recipients. OBJECTIVE: To assess the role of ATP in terminating fast VTs in primary prevention ICD recipients with contemporary programming. DESIGN, SETTING, AND PARTICIPANTS: This global, prospective, double-blind, randomized clinical trial had an equivalence design with a relative margin of 35%. Superiority tests were performed at interim analyses and the final analysis if equivalence was not proven. Patients were enrolled between September 2016 and April 2021 at 134 sites in 8 countries, with the last date of follow-up on July 6, 2023. Patients were required to have an indication for a primary prevention ICD, including left ventricular ejection fraction less than or equal to 35%. INTERVENTIONS: Patients were randomized in a 1:1 ratio to receive ATP plus shock vs shock only. MAIN OUTCOMES AND MEASURES: The primary end point was time to first all-cause shock. Secondary end points included time to first appropriate shock, time to first inappropriate shock, all-cause mortality, and the composite of time to first all-cause shock plus all-cause mortality. RESULTS: A total of 2595 patients were randomized (mean age, 63.9 years; 22.4% were females). At a mean follow-up of 38 months, first all-cause shock occurred in 129 participants in the ATP plus shock group and 178 participants in the shock only group. The hazard ratio (HR) for the primary end point was 0.72 (95.9% CI, 0.57-0.92), with P = .005 for superiority of the ATP plus shock group over the shock only group. During follow-up in an intention-to-treat analysis, the total shock burden per 100 patient-years was not statistically different, at 12.3 and 14.9, respectively (P = .70). CONCLUSIONS AND RELEVANCE: The use of a single burst of ATP prior to shock in primary prevention ICD recipients with modern ICD detection programming prolonged the time to first all-cause ICD shock. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02923726.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。