Comparison of the lower uterine segment in pregnant women with and without previous cesarean section in 3 T MRI

3T磁共振成像中既往有剖宫产史和无剖宫产史的孕妇子宫下段的比较

阅读:2

Abstract

BACKGROUND: Prenatal risk stratification of women with previous cesarean section (CS) by ultrasound thickness measurement of the lower uterine segment (LUS) is challenging. There is a wide range of proposed cutoff values and a valuable algorithm for selection before birth is not available. Using 3 T magnetic resonance imaging (MRI), we aimed to identify possible shortcomings of the current protocols used for birth selection after CS. Therefore, we evaluated anatomic and morphologic differences of the LUS and its thickness in patients with CS and those without. Possible impact factors on LUS thickness were studied. METHODS: We retrospectively analyzed 3 T MRI scans of 164 pregnant women in their second or third trimester, with (patient group, n = 60) and without previous CS (control group, n = 104). Sagittal T2-weighted images were studied. Normal findings of the LUS in MRI, reliability of MRI measurements, as well as factors influencing LUS thickness were assessed. MRI findings were compared to intraoperative findings. RESULTS: MRI provided good intra- (ICC 0.872) and fair inter-rater reliability (ICC 0.643). The relationship of the LUS and the cesarean scar to the surrounding anatomical structures and also its morphology varied strongly in patients and controls. Scar identification was possible in only 9/60 (15.0%) patients. The LUS was thinner in patients (1.9 ± 0.7 mm) than in controls (2.7 ± 1.3 mm). An LUS thinning up to 1 mm was observed in 23% of women without a previous CS and in 34% of women with normal intraoperative findings. Suspicion of a uterine dehiscence (LUS thickness < 1 mm) was only found in the patient group (5/59 (8.5%)) and was intraoperatively confirmed. In controls, LUS thickness was influenced by fetal weight, gestational age and amniotic fluid amounts. CONCLUSION: Variability in anatomy, thickness and morphology seem to limit common prenatal LUS imaging diagnostics. Therefore, we consider that diagnostic protocols must be re-evaluated and imaging should be adjusted to the individual patient conditions. Due to its independency of ultrasound limitations, an additional MRI might be useful for altered anatomy and impaired ultrasound conditions. An LUS thinning up to 1 mm might be a normal finding and should be further investigated as reference value.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。