Diagnostic efficacy of single-pass abdominal multidetector-row CT: prospective evaluation of a low dose protocol

单次腹部多层螺旋CT的诊断效能:低剂量方案的前瞻性评估

阅读:1

Abstract

OBJECTIVE: To evaluate the diagnostic efficacy of single-pass contrast-enhanced multidetector CT (CE-MDCT) performed with a low-radiation high-contrast (LR-HC) dose protocol in selected patients with non-traumatic acute bowel disease. METHODS: 65 (32 males, 33 females; aged 20-67 years) consecutive patients with non-traumatic acute bowel disease underwent single-pass CE-MDCT performed 70-100 s after i.v. bolus injection of a non-ionic iodinated contrast medium (CM) (370 mgI ml(-1)). In 46 (70%) patients with a clinical and/or ultrasonographic suspicion of inflammatory bowel disease, up to 1.2-1.4 l of a 7% polyethylene-glycol solution was orally administered 45-60 mins prior to the CT examination. Patients were then divided into two groups according to age: Group A (20-44 years; n = 34) and Group B (45-70 years; n = 31). Noise index (NI) and CM dose were selected as follows: Group A (NI = 15; 2.5 ml kg(-1)) and Group B (NI = 12.5; 2 ml kg(-1)). All patients of Group A underwent thyroid functional tests at 4-6 weeks. Final diagnoses were obtained by open (n = 12) or laparoscopic surgery (n = 4), endoscopy w/without biopsy (n = 24) and clinical (n = 19) and/or instrumental (ultrasonography) (n = 6) follow-up at 11 ± 4 months (range 6-18 mo.). Statistical analysis was performed by χ(2) and Student's t-test for categorical and continuous variables, respectively. RESULTS: Sensitivity and specificity were 91.3 vs 95.4% (p = 0.905) and 90.9 vs 88.8% (p = 0.998) with an overall diagnostic accuracy of 91.1 vs 93.5% (p = 0.756), whereas the radiation (in millisievert) and CM dose (in millilitre) were 7.5 ± 2.8 mSv and 155 ± 30 ml for Group A and 14.1 ± 5.3 mSv and 130 ± 24 ml for Group B (p < 0.001), respectively. No patients of Group A showed laboratory signs of thyrotoxicosis at follow-up. CONCLUSION: The LR-HC has proved to be a safe and a dose-effective protocol in the evaluation of selected young patients with non-traumatic acute bowel disease. Advances in knowledge: (1) As reaching the highest diagnostic benefit to risk ratio (AHARA) appears to be the current principle of MDCT imaging, an increased amount of iodinated CM (0.7-0.9 gI ml(-1)) can be safely administered to young patients (<40 years) with normal thyroid and renal function to compensate for the lower image quality resulting from low-dose CT protocols performed with the standard filter back-projection algorithm. Such an approach will result in a significant reduction of the radiation dose, which could be otherwise achieved only using iterative reconstruction algorithms combined with either low tube voltage and/or low tube current protocols. (2) An optimal scan delay (T(delay)) for a venous phase caudocranial acquisition can be calculated by the following formula: T(delay) = CI + 25 - T(SD), where CI is the duration of the contrast injection, 25 is the average of the sum of abdominal aortic and peak hepatic arrival times and T(SD) is the scan duration. With such an approach, the radiation exposure resulting from bolus tracking, albeit performed with low-dose scans, can be spared in patients with normal transit times.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。