Development and Comparative Evaluation of Two Different Label-Free and Sensitive Fluorescence Platforms for Analysis of Olaparib: A Recently FDA-Approved Drug for the Treatment of Ovarian and Breast Cancer

开发和比较评价两种不同的无标记高灵敏度荧光平台用于分析奥拉帕尼:一种近期获得FDA批准用于治疗卵巢癌和乳腺癌的药物

阅读:2

Abstract

Olaparib (OLA) is a PARP inhibitor drug which has been recently approved by the Food and Drug Administration (FDA) for the treatment of ovarian and breast cancer. A convenient analytical tool for the quantitation of OLA in its dosage form and plasma samples was urgently needed. This study describes, for the first time, the development of two different label-free and sensitive fluorescence-based platforms for the pharmaceutical and bioanalysis of OLA. These platforms were microwell-assisted with a fluorescence microplate reader (MW-FLR) and high-performance liquid chromatography with fluorescence detection (HPLC-FD). Both MW-FLR and HPLC-FD employed the native fluorescence of OLA as an analytical signal. The MW-FLR involved measuring the fluorescence signals in 96-well white-opaque plates. The HPLC-FD involved chromatographic separation of OLA and duvelisib (DUV), as an internal standard on a Nucleosil-CN HPLC column (250 mm length × 4.6 mm i.d., 5 µm particle diameter) with a mobile phase composed of acetonitrile: water (25:75, v/v) pumped at a flow rate of 1.7 mL/min. Elution of OLA and DUV was detected using a fluorescence detector. The optimal conditions of both MW-FLR and HPLC-FD were established, and they were validated according to the guidelines of the International Council for Harmonization for the validation of analytical procedures. The linear ranges of MW-FLR and HPLC-FD were 25-1000 and 5-200 ng/mL, respectively, with limits of detection of 15 and 1.7 ng/mL, respectively. The accuracy and precision of both platforms were confirmed as the recovery values were ≥98.2% and the relative standard deviations (RSD) were ≤2.89%. Both methodologies were satisfactorily applied to the quantitation of OLA in its commercial dosage form (Lynparza(®) tablets) and plasma samples with high accuracy and precision. The greenness of both MW-FLR and HPLC-FD was assessed using two different multiple parameter-based metric tools, and the results proved their greenness and adherence to the requirements of green analytical approaches. Both platforms have simple procedures and acceptable levels of analytical throughput. In conclusion, the proposed MW-FLR and HPLC-FD are valuable tools for routine use in quality control and clinical laboratories for the quantitation of OLA for the purposes of pharmaceutical quality control, pharmacokinetic studies, and bioequivalence testing.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。